General Description • Standard Features • Specifications
For PM and Shunt Motors Rated:
1/50 – 3/4 HP (SCR), 1 HP (PWM) @ 115 VAC
1/25 – 11⁄2 HP (SCR), 2 HP (PWM) @ 230 VAC
Rated 7.5 Amps DC, 11.5 Amps AC @ 115/230 VAC
Washdown and Watertight for Indoor and Outdoor Use
Standard Features
• Short Circuit Protection: Protects control from short circuits.
• Electronic Motor Burnout Protection: Shuts down the control if a prolonged overload condition exists.
• Active Bridge: Limits AC Line inrush current.
• Power Transistor Short Circuit Protection: Prevents high speed runaway if the power transistor shorts.
• Heat Spreader: Prevents power transistor failure during momentary overload conditions.
• LEDs: Power on (ON), Stop (STOP) and Overload (OL).
• Auto AC Line Select: Control automatically adjusts for 115 VAC or 230 VAC – 50/60 Hz.
• Start/Stop Switch: Provides electronic start/stop function.
• Output Run Relay: Indicates state of control – (Run or Stop)
Jumper Selectable Features
• J1 (T/90V/180V) selects nominal motor voltage or tachometer generator feedback.
• J2 (1.7A, 2.5A, 3.5A, 5.0A, 7.5A, also low current range) selects motor current. See general performance specifications.
• J3 (TCL/NTCL) selects timed or non-timed current limit.
• J4 (7V/50V) selects tachometer generator voltage.
• J5 (NC/NO) selects normally closed or open run relay contacts.
Trimpot Adjustments
• Acceleration (ACCEL) • Deceleration (DECEL)
• Maximum Speed (MAX) • Minimum Speed (MIN)
• Current Limit (CL) • Timed Current Limit (TCL)
• IR Compensation (IR) • Jog (JOG)
Optional Features
• On/Off AC line switch (P/N 9341): Disconnects the AC line.
• FWD-BRK-REV switch (P/N 9339): Provides reversing and dynamic braking.
• Run-Stop-Jog switch (P/N 9340): Selects speed setting from either main potentiometer or JOG trimpot.
• Signal Isolator KBSI-240D (P/N 9431): Provides isolation between non-isolated signal sources and the KBPW-240D.
• Anti-Plug Reversing Module APRM (P/N 9378A): Provides electronic braking and instant reversing.
• Auto/Manual Switch (P/N 9377): Selects either isolated signal (from KBSI-240D) or main speed potentiometer signal.
*Note: Requires CE RFI filter KBRF-200A (KB P/N 9945) or equivalent.
VIEW INSTRUCTION MANUAL
View Data Sheet
For more information about this product,
call 1-888-286-8614 or e-mail us today!
General Description • Standard Features • Specifications
Back to DC Drives • Back to Product Line
Vous cherchez des sources fiables pour acheter steroide sur Internet ? Pourbien choisir, voici le steroide fr avis des utilisateurs sur les meilleurs shops.
Discover the world of gambling at houseofpokies. Also explore the exciting slots at HouseofPokies
Welcome to https://casino-winorama.com/ in 2023! Experience thrilling games and big wins. Ready to rocket your luck?
Dive into the thrill at Apollo Slots Casino! Start your adventure with an easy Apollo Slots mobile login from anywhere in South Africa!