General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Model Ratings and Dimensions
Non-Regen Standard Models
230 VAC
Input |
460 VAC
Input |
Model Number
|
Description
|
Size (in.)
|
Wt.
(lbs.) |
||
---|---|---|---|---|---|---|---|
H
|
W
|
D
|
|||||
5-10 HP | 5-20 HP | E06020-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 65 |
15-20 HP | 25-40 HP | E06040-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 65 |
25-30 HP | 50-60 HP | E06060-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 65 |
40 HP | 75 HP | E06075-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 65 |
50 HP | 100 HP | E06100-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 70 |
60 HP | 125 HP | E06125-000 | Chassis only, basic non-regen model |
22.5
|
12.25 | 11 | 70 |
75 HP | 150 HP | E06150-000 | Chassis only, basic non-regen model |
26.5
|
12.25 | 11 | 75 |
100 HP | 200 HP | E06200-000 | Chassis only, basic non-regen model |
38
|
50 | 12 | 20 |
125 HP | 250 HP | E06250-000 | Chassis only, basic non-regen model |
38
|
50 | 12 | 200 |
150 HP | 300 HP | E06300-000 | Chassis only, basic non-regen model |
38
|
50 | 12 | 200 |
Non-Regen Contactor Models
230 VAC
Input |
460 VAC
Input |
Model Number
|
Description
|
Size (in.)
|
Wt.
(lbs.) |
||
---|---|---|---|---|---|---|---|
H
|
W
|
D
|
|||||
5-10 HP | 10-20 HP | E06020-C20 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
39
|
33 | 12 | 125 |
15-20 HP | 25-40 HP | E06040-C40 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
39
|
33 | 12 | 125 |
25-30 HP | 50-60 HP | E06060-C60 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
39
|
33 | 12 | 125 |
40 HP | 75 HP | E06075-C75 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
39
|
33 | 12 | 165 |
50 HP | 100 HP | E06100-C100 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
45
|
33 | 12 | 180 |
60 HP | 125 HP | E06125-C125 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
56
|
45 | 12 | 190 |
75 HP | 150 HP | E06150-C150 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
56
|
45 | 12 | 200 |
100 HP | 200 HP | E06200-C200 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
68
|
56 | 12 | 350 |
125 HP | 250 HP | E06250-C250 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
68
|
56 | 12 | 350 |
150 HP | 300 HP | E06300-C300 | Non-regenerative run/stop chassis model w/ arm. contactor & control XFMR |
68
|
56 | 12 | 350 |
Regen Standard Models
230 VAC
Input |
460 VAC
Input |
Model Number
|
Description
|
Size (in.)
|
Wt.
(lbs.) |
||
---|---|---|---|---|---|---|---|
H
|
W
|
D
|
|||||
5-10 HP | 5-20 HP | E12020-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 65 |
15-20 HP | 25-40 HP | E12040-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 65 |
25-30 HP | 50-60 HP | E12060-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 65 |
40 HP | 75 HP | E12075-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 65 |
50 HP | 100 HP | E12100-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 70 |
60 HP | 125 HP | E12125-000 | Chassis only, basic regen model |
22.5
|
12.25 | 11 | 70 |
75 HP | 150 HP | E12150-000 | Chassis only, basic regen model |
26.5
|
12.25 | 11 | 75 |
100 HP | 200 HP | E12200-000 | Chassis only, basic regen model |
38
|
50 | 12 | 200 |
125 HP | 250 HP | E12250-000 | Chassis only, basic regen model |
38
|
50 | 12 | 200 |
150 HP | 300 HP | E12300-000 | Chassis only, basic regen model |
38
|
50 | 12 | 200 |
Regen Contactor Models
230 VAC
Input |
460 VAC
Input |
Model Number
|
Description
|
Size (in.)
|
Wt.
(lbs.) |
||
---|---|---|---|---|---|---|---|
H
|
W
|
D
|
|||||
5-10 HP | 10-20 HP | E12020-C20 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
39
|
33 | 12 | 125 |
15-20 HP | 25-40 HP | E12040-C40 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
39
|
33 | 12 | 125 |
25-30 HP | 50-60 HP | E12060-C60 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
39
|
33 | 12 | 125 |
40 HP | 75 HP | E12075-C75 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
39
|
33 | 12 | 165 |
50 HP | 100 HP | E12100-C100 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
45
|
33 | 12 | 180 |
60 HP | 125 HP | E12125-C125 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
56
|
45 | 12 | 190 |
75 HP | 150 HP | E12150-C150 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
56
|
45 | 12 | 200 |
100 HP | 200 HP | E12200-C200 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
68
|
56 | 12 | 350 |
125 HP | 250 HP | E12250-C250 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
68
|
56 | 12 | 350 |
150 HP | 300 HP | E12300-C300 | Regenerative run/stop chassis model with arm. contactor and control XFMR |
68
|
56 | 12 | 350 |
VIEW INSTRUCTION MANUAL LOW HP MODELS
VIEW INSTRUCTION MANUAL HIGH HP MODELS
SERVICE MANUAL
View Brochure
General Description • Standard Features • Specifications • Model Ratings/Dimensions • Connections
Back to DC Drives • Back to Product Line
Vous cherchez des sources fiables pour acheter steroide sur Internet ? Pourbien choisir, voici le steroide fr avis des utilisateurs sur les meilleurs shops.
Discover the world of gambling at houseofpokies. Also explore the exciting slots at HouseofPokies
Welcome to https://casino-winorama.com/ in 2023! Experience thrilling games and big wins. Ready to rocket your luck?
Dive into the thrill at Apollo Slots Casino! Start your adventure with an easy Apollo Slots mobile login from anywhere in South Africa!