A.C.
INPUT
115 VAC 50/60 Hz, internally
fused at 0.3 AMPS
ISOLATION
VOLTAGE
2400V peak at 1 second
or 1500 VRMS
LINEARITY
±0.5% of 10 VDC span
SIGNAL
INPUTS
Potentiometer Input (Input
A & B) +15 VDC available to source a 2K to 10K Ohm potentiometer.
The 10 VDC input range should be selected for this
type of input.
Voltage Input (Input A
& B)
7 selectable ranges with 100K to Ohm input impedance.
| Input Range |
Input Impedance |
| -100 mVDC to +100 mVDC |
100K |
| -1 VDC to +1 VDC |
1M |
| -2.5 VDC to +2.5 VDC |
100K |
| -10 VDC to +10 VDC |
10M |
| -2.5 VDC to +2.5 VDC |
1M |
| -100 VDC to +100 VDC |
10M |
| -250 VDC to +250 VDC |
10M |
Note: Negative input voltages cannot be used at
Input A when the D11005-000 is used in the Divide Mode of Operation. input
types
|
Auxiliary Input A
This allows a fixed or variable signal (-10 VDC to +10 VDC) to be summed
directly with the scaled input signal at Input A. Isolation is maintained
from the Auxiliary Input A to Input B signals and the Output.
Auxiliary Input B
This allows a fixed or variable signal (-10 VDC to +10 VDC) to be summed
directly with the scaled input signal at Input B. Isolation is maintained
from the Auxiliary Input B to Input A signals and the Output.
Summing Input
This input allows a fixed or variable signal (-10 VDC to +10 VDC) to be
summed directly with the output. Isolation is not maintained between the
summing input and the output.
OUTPUT
TYPES
Voltage Output
This circuit allows the output to source a voltage level into a minimum
resistance of 500 OHMS. (Lower load resistance may affect output linearity.)
Current Output
This circuit allows the output to source a regulated current of up to
20mA into a maximum resistance of 500 OHMS. Using the BIAS Potentiometer,
the output can source a 4-20mA signal.
Meter Output
This output can be used to source a voltage level to a meter with a minimum
2K internal resistance. Its range can be set by the METER RANGE Potentiometer.
|