A.C. Input
230 VAC ± 10%,
3 phase, 50/60 Hz ± 2 Hz
460 VAC ± 10%,
3 phase, 50/60 Hz ± 2 Hz
Armature Output
0- 240 VDC
@ 230 VAC input
0-
500 VDC @ 460 VAC input
Field Output
150 VDC @ 230
VAC input, 10 Amps max.
300
VDC @ 460 VAC input, 10 Amps max.
Horsepower Range
Model CDC320-000
10 HP @ 240 VDC, 36 Amps
20 HP @ 500 VDC, 36 Amps
Model
CDC340-000
20 HP @ 240 VDC, 71 Amps
40 HP @ 500 VDC, 71 Amps
Model
CDC360-000
30 HP @ 240 VDC, 107 Amps
60 HP @ 500 VDC, 107 Amps
Model
CDC375-000
40 HP @ 240 VDC, 140 Amps
75 HP @ 500 VDC, 140 Amps
Model
CDC3150-000
75 HP @ 240VDC, 256 Amps
150 HP @ 500VDC, 256 Amps
Speed Regulation
Armature Feedback: ± 1.0%
of base speed
Tachometer
or Encoder Feedback: ± 0.5%
of base speed
Torque Regulation
±2%
of range selected |
Adjustments
Minimum Speed:
0 to 30% of Base Speed
Maximum
Speed: 0 to 110% of Base Speed
Jog
Speed: 0 to 25% of Base Speed
Sum
Trim: 0 to 100% of Summing Input
Acceleration:
1 to 60 seconds
Deceleration:
1 to 60 seconds
Voltage
Gain: AppOctober 16, 2006riangle.gif" width="13" /> Current
Gain: Application dependent
IR
Compensation: Range set by Current Range Jumper
Current
Limit: 0 to 150% of Current Range
Current
Calibration: Factory adjustment
Current
Offset: Factory adjustment
Bal
1: Factory adjustment
Bal
2: Factory adjustment
Speed Range
Dependent upon
motor cooling
20:1 with Armature Feedback
50:1 with Tach or Encoder Feedback
Temperature Range
0 - 55ºC
for chassis units
0 - 40ºC
for enclosed units |